Email:[email protected]

four path boiler exhaust temp

Hot Products
Capacity:1-20 t/h
Pressure:0.7-2 Mpa
Read More
Capacity:2 – 20t/h
Pressure:1 - 2.5 MPA
Read More
Capacity:20-75 t/h
Pressure:1.25-5.4 MPA
Read More
Capacity:7000-29000 KW
Pressure:0.8-1.0 MPA
Read More
  • specifying high-temperature hot-water boilers and systems

    Specifying high-temperature hot-water boilers and systems

    As it relates to steam and per Section I of ASME, a power boiler is “a boiler in which steam or another vapor is generated at a pressure of more than 15 psig (100 kPa) for use external to itself,” and a heat-recovery steam generator (HRSG) is “a boiler that has as its principal source of thermal energy a hot gas stream having high-ramp rates and temperatures such as the exhaust of a gas turbine.” HRSGs are …

    View More
  • exhaust temperature - an overview | sciencedirect topics

    Exhaust Temperature - an overview | ScienceDirect Topics

    Figs. 4.8–4.12 illustrate sample heat recovery cases used to construct Fig. 4.7. Fig. 4.8 shows an optimized one (single) pressure non-reheat cycle with 500°C gas turbine exhaust temperature. Fig. 4.9 shows the significant improvement available from additional steam generation pressures versus the optimized single-pressure design of Fig. 4.8, both at 500°C exhaust gas temperature. Fig. 4.10 at …

    View More
  • exhaust gas - an overview | sciencedirect topics

    Exhaust Gas - an overview | ScienceDirect Topics

    High loads and high speeds result in the highest temperatures. Generally, temperatures of 500–700°C (932–1293°F) are produced in the exhaust gases from diesel-cycle engines at 100% load to 200–300°C (392–572°F) with no load. Exhaust gases normally discharges at a temperature of around 420°C (788°F).

    View More
  • gas turbine exhaust temperature control curve | automation & …

    Gas Turbine Exhaust Temperature Control Curve | Automation & …

    03-01-2009 · And the firing temperature represents the combustion gas temperatures that are being experienced by the hot gas path components (combustion liners, transition pieces, turbine nozzles, turbine buckets, exhaust components). So, it's important to limit and control this temperature to maximize parts life while still producing as much power as possible. The calculations include things …

    View More
  • improving energy efficiency of boiler systems

    Improving Energy Efficiency of Boiler Systems

     · PDF file

    IMPROVING ENERGY EFFICIENCY OF BOILER SYSTEMS When considering boiler energy savings, invariably the discussion involves the topic of boiler efficiency. The boiler suppliers and sales personnel will often cite various numbers, like the boiler has a thermal efficiency of 85%, combustion efficiency of 87%, a boiler efficiency of 80%, and a fuel-to-steam efficiency of 83%. What does these mean? …

    View More
  • fuels exhaust temperatures - engineering toolbox

    Fuels Exhaust Temperatures - Engineering ToolBox

    Exhaust Temperature (o F) (o C) Chemical Oxidation: 1350 - 1475: 730 - 800: Annealing furnace: 1100 - 1200: 590 - 650: Fluidized-bed combustion: 1600 - 1800 : 870 - 980: Natural-gas fired heating appliance with draft hood: 360: 182: Liquefied-petroleum gas-fired heating appliance with draft hood: 360: 182: Gas-fired heating appliance, no draft hood: 460: 238: Glass melting furnace: 1200 - 1600: 650 - 870: …

    View More
  • flue gas analysis table | cleanboiler.org

    Flue Gas Analysis Table | CleanBoiler.org

    Flue Gas Analysis Table Introduction . See Flue Gas Analysis. Operation. Using a Flue Gas Analyzer or any meter designed to measure oxygen or carbon-monoxide, and taking the flue gas temperature and the temperature of the combustion air, the following Table can be used to determine combustion efficiency when operating on natural gas. The Temperature Column is the NET Difference between …

    View More
  • boiler efficiency guide - cleaver-brooks

    BOILER EFFICIENCY GUIDE - Cleaver-Brooks

     · PDF file

    heat to the water in the boiler. A 4-pass design provides four opportunities for heat transfer. The stack temperature of a 4-pass boiler will be lower than the stack temperature of a 2 or 3-pass boiler, of the same basic design, operating under similar conditions. Because of this fact, the 4-pass will have higher efficiency and lower fuel cost

    View More

Tel:+86-13506151306

Email:[email protected]

Addr: No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China