Hot Products
Capacity:1-20 t/h
Pressure:0.7-2 Mpa
Read More
Capacity:2 – 20t/h
Pressure:1 - 2.5 MPA
Read More
Capacity:20-75 t/h
Pressure:1.25-5.4 MPA
Read More
Capacity:7000-29000 KW
Pressure:0.8-1.0 MPA
Read More
  • steam boiler capacity calculation--zozen

    Steam Boiler Capacity Calculation--Zozen

    Steam Boiler Capacity Calculation 11-02. Many customers contact us online with the question of calculation of boiler capacity. they don't know how to calculate the boiler capacity they need. For example: It is common to express the output of fire tube and water tube steam boilers in Boiler Horsepower, MBTU or in Pounds of Steam delivered per hour. W = (hg - hf) m where W = boiler …

    View More
  • fire tube boiler capacity calculation--zozen

    Fire Tube Boiler Capacity Calculation--Zozen

    Fire Tube Boiler Capacity Calculation 2018-08-03 08:43:52. A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or (many) more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.

    View More
  • capacity of a fire tube boiler - the h & s foundation

    Capacity Of A Fire Tube Boiler - The H & S Foundation

    boiler contains a safety valve that, when the pressure becomes too high due to blockage or overheating, releases the excess steam. Project Description Our engineering team designed a three­pass fire tube steam boiler with a capacity of 5000 kg of steam per hour and a operating pressure of 10 bar.

    View More
  • boiler calculations for steam, hot water and thermal loads

    Boiler Calculations for Steam, Hot Water and Thermal Loads

    S.P. Thermal Systems provides boiler calculations, for steam boiler loads, boiler efficiency, hot water loads, thermal load, boiler operating cost to determine if changes to your operation is justified. It is important to note that S.P. Thermal Systems Inc. is not responsible for evaluating, or sizing your system, and strongly recommends that if you are not familiar with the design of these systems, to have a …

    View More
  • how to calculate the steam drum tank size of a vertical water tube

    How to calculate the steam drum tank size of a vertical water tube

    I think you’re putting the cart before the horse. First of all, you need to determine how many square feet of surface on the interiors of the fire tubes are needed to transfer sufficient heat to generate the needed amount of steam. The associated

    View More
  • boiler capacity - engineering toolbox

    Boiler Capacity - Engineering ToolBox

    W = boiler capacity (Btu/h, kW) h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is . the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with feedwater at 0 Psig and 212 o F. A BHP is equivalent to 33,475 BTU/Hr or …